Aspirating

ASD Systems

ASD Systems

Aspirating smoke detection involves actively drawing air from the protected area through a network of air sampling pipes, passing it through a central detection device, and sampling it for smoke.

The device uses an opening in a specifically made reflector to direct a strong laser, which is based on the forward light scatter concept.

Light is focused on a single photo-receiver and is scattered on the reflector by any combustion products in the flowing air sample.

ASD System Types

Stratos HSSD 2

The Stratos HSSD 2 is made to detect smoke across wide areas with extremely high sensitivity. Without requiring complicated setup, ClassiFire Perceptive Artificial Intelligence guarantees that the detector performs at maximum sensitivity for the protected environment. This implies that the detector will set itself up to be less sensitive in a smokey location or more sensitive in a computer room. Compatibility with any fire alarm system is guaranteed via voltage-free contacts. There are three monitored inputs available for each detector. For complete information, refer to the technical documentation. The inputs can be set up for various purposes.

  • Aspirating smoke detector with a large coverage area of up to 2000 square meters .
  • For dependable early warning, laser-based forward light scatter offers high sensitivity.
  • Approved by EN54 Part 20.
  • The unique ClassiFire® Perceptive Artificial Intelligence technology dynamically modifies the detector's working settings to account for daily variations in the system contaminants and protected environment.
  • The unique Dual Technology LDD 3D3 Laser Dust Discrimination and Elimination system prevents unwanted dust alerts.
  • Four sampling pipes with a maximum total length of 200 metersThe standard for networking and remote communications is RS485 communications.

Micro 100

The Stratos-Micra 100 is made to detect smoke with extremely high sensitivity in a compact form.

Without requiring complicated setup, ClassiFire Perceptive Artificial Intelligence guarantees that the detector performs at maximum sensitivity for the protected environment. This implies that the product will set itself up to deliver low sensitivity in a smokey location or high sensitivity in a computer room. The detector is made to be installed in a docking station. As a preliminary fix, all sample pipes and cables are attached to the Docking Station; if necessary, the detector will be installed at the final commissioning stage. By doing this, the likelihood of detectors being harmed during installation is reduced. Compatibility with any fire alarm system is guaranteed via voltage-free contacts. 

  • Aspirating smoke detectors are small, inexpensive, and easy to install covertly.
  • For dependable early warning, laser-based forward light scatter offers high sensitivity.
  • For flexibility, two 100-meter aggregate sampling pipelines
  • The unique ClassiFire® Perceptive Artificial Intelligence technology dynamically modifies the detector's working settings to account for daily variations in the system contaminants and protected environment.
  • The unique Dual Technology LDD 3D3 Laser Dust Discrimination and Elimination system prevents unwanted dust alerts.
  • Approved by EN54 Part 20.

Micro 25

The Stratos-Micra 25 is made to detect smoke with extremely high sensitivity in a compact form.

Without requiring complicated setup, ClassiFire Perceptive Artificial Intelligence guarantees that the detector performs at maximum sensitivity for the protected environment. This implies that the product will set itself up to deliver low sensitivity in a smokey location or high sensitivity in a computer room. The detector is made to be installed in a docking station. As a preliminary fix, all sample pipes and cables are attached to the Docking Station; if necessary, the detector will be installed at the final commissioning stage. By doing this, the likelihood of detectors being harmed during installation is reduced. Compatibility with any fire alarm system is guaranteed via voltage-free contacts. 

  • Aspirating smoke detectors are small, inexpensive, and easy to install covertly.
  • For dependable early warning, laser-based forward light scatter offers high sensitivity.
  • A single, 50-meter-long (still air) sampling pipe.
  • The unique ClassiFire® Perceptive Artificial Intelligence technology dynamically modifies the detector's working settings to account for daily variations in the system contaminants and protected environment.
  • The unique Dual Technology LDD 3D3 Laser Dust Discrimination and Elimination system prevents unwanted dust alerts.
  • Approved by EN54 Part 20

Stratos Nano

Stratos-Nano is a compact, simple-to-install device that offers dependable aspirating smoke detection. The detector comes with an ABS enclosure. Simple on-site programming is made possible via an integrated DIL switch, which eliminates the requirement for a laptop computer or specialized programmer. Without requiring complicated setup, ClassiFire Perceptive Artificial Intelligence guarantees that the detector performs at maximum sensitivity for the protected environment. This implies that the product will set itself up to deliver low sensitivity in a smoke-filled atmosphere or great sensitivity in a compact communications room.Compatibility with any fire alarm system is guaranteed via voltage-free contacts. 

  • Intended to provide situations where cost would have previously restricted installations to "point detector in a fan box" type systems with the advantages of laser-based aspirating smoke detection.
  • For dependable early warning, laser-based forward light scatter offers high sensitivity.
  • The airflow issues with "point-in-a-box" systems are avoided with a laser smoke sensor chamber specifically made for aspirating detection.
  • Ten sampling holes and a maximum 50-meter sampling pipe.
  • The unique Dual Technology LDD 3D3 Laser Dust Discrimination and Elimination system prevents unwanted dust alerts.
  • Simple commissioning without a computer.
  • Approved by EN54 Part 20.

Command Module

Up to 127 detectors can be controlled via a network.

Communications RS485 Integrated Short Isolators for Maximum Dependability Programmable Integral Serial Interface for BACnet BMS communications or TAP text messaging/paging The SenseNET PC Graphical Management System's RS232 serial interface either separately or in combination with the HSSD 2 detector enclosure For networks with up to 127 detectors, the Stratos Command Module offers a single location display, control, and interface option. From a single central point, any detector on the network can be programmed or questioned. The engineer can modify configuration settings on every detector at once thanks to global programming. In order to spot possible trouble spots, the Command Module will by default always show the status of the detector with the greatest smoke level. The common set of alarm and fault relays in the command module can simplify the interface of all detectors on the network. The command module can link all networked detectors into an addressable loop from a single location by using an APIC (addressable Protocol link Card). Every detector on the network will get status information from the APIC, and the fire alarm control panel will display each detector's unique address. The Modbus output on the Command Module makes it simple to interface with the customer's BMS system. On request, Kidde Airsense will supply the Modbus protocol document. The command module can also be included as part of a Stratos HSSD 2, which combines central control and indication with detecting capabilities in a single enclosure to conserve space and shorten installation times. For more industrial applications, a steel enclosure version of the command module is also offered.

Applications

  • Apartments
  • Hotels
  • Shops
  • Offices
  • Correctional Facilities
  • Clean Rooms
  • Cold Storage
  • Cultural/Heritage
  • Data Centres
  • Telecom Centres
  • Hospitals
  • Healthcare
  • Insurance
  • Marine
  • Nuclear Facilities
  • Oil & Gas
  • Portable Switch Rooms
  • Power Generation
  • Records Storage
  • Transportation
  • Waste Facilities
  • Recycling Facilities
  • Wind Power Generation
  • Warehousing

For a free ASD quote, contact us right now.

Enquire Now